“Thou shalt not curse the deaf, nor put a stumblingblock before the blind, but shalt fear thy God: I am the Lord.”
Leviticus 19:14, King James Version, from the Holiness Code of the Hebrew Bible
Many church leaders believe their building does not have to be accessible because churches are exempt from the ADA. Half of that sentence is true. Federal law does exempt religious organizations from the part of the Americans with Disabilities Act that governs buildings open to the public. But the ADA requirements for churches were never the rules that decide whether your new sanctuary gets a ramp to the platform or a restroom a wheelchair can turn around in. Those rules live in the building code your city or county adopted, and that code has no general exemption for churches at all.
We start every church project by sorting out which of these two systems governs which decisions, because confusing them is one of the more disruptive misunderstandings a building committee can carry into design. A committee that believes it is exempt tends to sketch a platform with six steps and no ramp, a balcony with no elevator, and a renovation plan that never touches the restrooms. Then plan review returns the drawings with comments, and the fixes arrive late, when they fit the worst and disturb the most. What follows is how that sorting works, what the code actually asks of a worship building, and the few places where it genuinely gives churches room.
Where the ADA requirements for churches stop
The exemption is written into the statute itself. The section of federal law that lists Title III’s exemptions states that its provisions do not apply to “religious organizations or entities controlled by religious organizations, including places of worship.” The Department of Justice reads that broadly in its Title III Technical Assistance Manual, the guidance it issued to explain the law. The exemption covers all of a religious entity’s activities, religious or secular, so a congregation that runs a day care or a school for members and nonmembers alike remains exempt from Title III.
The same guidance also marks the edges, and churches run into those edges more often than they expect. A private day care or school that rents space in the church building is not exempt unless it is itself a religious entity, and when it pays rent or other consideration, its activities in that space fall under Title III even though the congregation as landlord stays exempt. Space donated to a nonreligious group is treated differently, and the manual says that group is exempt when no lease or payment exists. The exemption also stops at Title III, since the manual notes that a religious entity is still subject to the ADA’s employment obligations in Title I if it has enough employees to be covered, which can bear on offices, workrooms, and staff areas.
From the research
“The private entity that rents the congregation’s facilities to operate a place of public accommodation is not exempt, unless it is also a religious entity.”
U.S. Department of Justice, ADA Title III Technical Assistance Manual, III-1.5200 Scope of exemption
For most congregations, though, the exemption is a fact about federal civil rights liability rather than a design rule. It means a person generally cannot bring a Title III claim against the church over its building. It does not mean the city will issue a permit for a building that leaves people out. The exemption decides who can sue the church, and the building code decides what the church is allowed to build.
The exemption decides who can sue the church, and the building code decides what the church is allowed to build.
Where church accessibility requirements really come from
When a city or county adopts the International Building Code, it adopts Chapter 11, the accessibility chapter, along with everything else in the book. Section 1103.1 of the 2021 edition sets the scope in one sentence: “Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to individuals with disabilities.” Chapter 11 then points designers to a companion standard, ICC A117.1, for the technical details of ramps, doors, restrooms, and reach ranges. Because the adopted code is local law enforced through plan review and inspection, it applies to a church the same way it applies to a restaurant or an office building, and the federal exemption has nothing to say about it.
This is why we treat accessibility as part of the code analysis at the very start of design rather than a checklist at the end. As we wrote about reading the building code before drawing anything, the first questions are which jurisdiction governs, which edition it adopted, and what it changed with local amendments. Accessibility follows the same path, and a jurisdiction on an older edition may number sections differently or carry slightly different exceptions than the 2021 text quoted here. Where no local building code has been adopted, the conversation changes, but the ADA exemption still does not become a design standard, and we would design to the code anyway for reasons that have nothing to do with enforcement.
Those reasons are sitting in your seats. The Centers for Disease Control and Prevention reported that 28.7 percent of U.S. adults described a functional disability in 2022 survey data, and among adults 65 and older the figure was 43.9 percent. That count covers difficulty with walking and stairs, hearing, vision, thinking and memory, and self-care, so it reaches well past the wheelchair user most people picture when they hear the word accessible. A congregation with a large senior ministry is designing for those people whether the drawings acknowledge them or not.
What the code asks of a worship space
The requirement most committees meet first is the count of wheelchair spaces in the worship room. In assembly spaces with fixed seating, which in most sanctuaries means pews or chairs fastened to the floor, Table 1109.2.2.1 of the 2021 IBC sets a minimum that rises with capacity. A room of 301 to 500 seats needs six wheelchair spaces, and above 500 the table adds one more for each 150 seats or fraction of 150, so an 800-seat auditorium needs eight. The count is the easy part. Where those spaces go is a design decision as much as a code one, because a row of empty slots at the very back meets the number while telling a family exactly where they are expected to sit.
The platform is where church projects most often collide with Chapter 11. Section 1109.2.8 says that where a circulation path directly connects a performance area to the assembly seating area, an accessible route has to make that same connection, and an accessible route also has to reach the ancillary spaces performers use. A contemporary worship stage with steps down to the front row, a green room behind it, and a choir or band that rotates every week fits that description closely. That usually means a ramp or a lift designed into the platform from the first sketch, because a ramp added after the stage is framed tends to eat the front of the room or wrap awkwardly around the side.
The code does give worship buildings two specific allowances, and they are worth knowing precisely because committees tend to stretch them. Section 1103.2.8 exempts raised or lowered areas in places of religious worship that are under 300 square feet, sit 7 inches or more above or below the floor, and are used primarily for the performance of religious ceremonies. A small pulpit platform or a baptistry platform may qualify, while a 900-square-foot stage built for a band, a drama team, and a children’s program usually will not, and whether a given platform qualifies is a reading the building official makes. The second allowance sits in the exceptions to Section 1109.2.4, which let a worship room put all of its wheelchair spaces on the main level when the balcony or mezzanine holds 25 percent or less of the total seating.
Worth knowing
Being exempt from Title III of the ADA does not exempt a church from Chapter 11 of the building code. If your city or county has adopted the IBC, plan review will check accessibility on your church the same way it checks exits and fire separations.
Renovations and the accessible route
Existing buildings follow a different code, the International Existing Building Code, and its accessibility rules attach to the work you choose to do. Section 306.7 of the 2021 edition requires an altered facility to comply with Chapter 11 of the IBC and ICC A117.1 unless that is technically infeasible, and where it is, the alteration has to provide access to the maximum extent technically feasible. The altered space itself has to meet the code. The bigger question for most church renovations is what happens to everything between the front door and that space.
Section 306.7.1 answers that. When an alteration affects or contains an area of primary function, meaning a space where the building’s main activities happen, the route to that area has to be accessible, including the toilet facilities and drinking fountains that serve it. The code caps that obligation: the cost of providing the accessible route is not required to exceed 20 percent of the cost of the alterations affecting the primary function area. A sanctuary renovation with new finishes, lighting, and a rebuilt platform therefore reaches past the sanctuary walls to the entrance, the corridor, and the restrooms that congregation uses on Sunday morning.
The same section lists what does not trigger the route requirement, and the list shapes how we sequence work. Alterations limited to windows, hardware, operating controls, electrical outlets, and signs do not trigger it, and neither do projects limited to mechanical or electrical systems, fire protection, or hazardous material abatement. Work undertaken for the primary purpose of increasing accessibility is also excluded, so a congregation that builds a ramp is not penalized with a second, larger obligation for doing so. When the building has to stay open through construction, the phasing we described for renovating a building that can’t close has to keep an accessible entrance and an accessible restroom working at every stage, which is easy to forget until the only ramp is behind a construction fence.
There is an honest counter-case here, and owners should hear it. If a church is not building or altering anything, neither the federal exemption nor the existing building code compels it to retrofit an old building, and a congregation in that position does genuinely have more latitude than a restaurant across the street. That latitude is real, but it is also the wrong frame for a project that is already underway. Once you are renovating, the code is in the room, and the only remaining choice is whether accessibility shapes the plan from the beginning or gets squeezed into whatever space is left at the end.
Worth asking
If we are not renovating, do we have to make our existing church building accessible?
Generally, no. The religious exemption removes Title III’s obligations for existing buildings, and the existing building code’s accessibility provisions attach to work you undertake, while requiring that features already accessible be kept that way. Many congregations still take on small, targeted improvements like an entrance ramp or a restroom, and because work done primarily to increase accessibility is excluded from the accessible route requirement, those projects stay the size you planned.
Does renting space to a preschool or a community group change anything?
It can. Under the Department of Justice guidance, a nonreligious tenant that pays rent to run a place of public accommodation, such as a private preschool, is covered by Title III for its activities even though the church as landlord stays exempt. If a tenant is part of the plan, its rooms, entrance, and restrooms deserve attention in design, and the lease should be clear about who is responsible for what.
Who decides whether our platform qualifies for the 300-square-foot exception?
The building official does, during plan review, based on the size, height, and primary use of the platform as drawn. A platform used mainly for preaching and sacraments reads differently from a stage used for bands, drama, and children’s programs, even at the same size. We raise the question with the jurisdiction early rather than design around an assumption that might not survive review.
Accessibility on a church project is rarely a question of whether, and almost always a question of when it enters the design. We bring it in at the first code analysis, alongside occupancy and exits, so the platform ramp, the wheelchair seating, and the route from the parking lot to the restrooms are shaped with the room instead of fitted into it afterward. Across more than a thousand church projects, we have learned where these requirements tend to surprise a committee and where the code genuinely gives a congregation room, and we would rather you hear both from us in the first meeting than from a plan reviewer months later. If your church is planning a new building or a renovation and you are not sure how these rules apply to it, we would be glad to talk it through with you.
Let’s Talk About Your Project
Every project starts with a conversation. If you have something in mind, or just a question, reach out and we will get back to you within one business day.